Define the required output
State field or force, measurement location, working gap, fixture and acceptable range. Include the mating steel or other magnetic-circuit parts.
Magnetic material selection
Read the grade, then check it in the finished magnetic circuit.
NdFeB magnet grades describe material properties. They do not specify the field at a sensor, holding force at a gap or allowable temperature of every finished shape. Those results also depend on dimensions, magnetization and the surrounding assembly.
Start with your required output and operating conditions. If a drawing already names a grade, include its data source and any proposed substitution restrictions.
Request a grade reviewUnderstand the grade
Confirm the material designation against the proposed part documentation.
How to read an NdFeB grade
Used in common designations for sintered neodymium-iron-boron material.
An approximate maximum energy-product class, commonly expressed in MGOe.
A suffix associated with intrinsic coercivity and thermal characteristics. Check the actual datasheet.
This is a naming example, not a stock declaration or an operating-temperature guarantee. M, H, SH, UH, EH and AH suffixes help screen material families, but a finished part still needs a circuit and temperature review.
Compare the same quantities
| Property | What it describes | What to check |
|---|---|---|
| Br — remanence | Material flux density after magnetization when the applied field returns to zero in the specified measurement. | It is not the field measured at your sensor or a specified distance from the part. |
| HcB — normal coercivity | The reverse-field value where magnetic flux density B reaches zero on the normal demagnetization curve. | Do not substitute it for intrinsic coercivity. |
| HcJ — intrinsic coercivity | Resistance to demagnetization expressed using the intrinsic polarization curve. | Compare the relevant temperature data and the actual opposing field. |
| (BH)max — maximum energy product | A material energy-product measure used to compare grade classes. | A higher grade number alone does not establish greater force in a different geometry. |
| Temperature-dependent curves | How the proposed material behaves over the temperatures being reviewed. | A generic maximum-temperature column does not establish a limit for every shape or assembly. |
Request the proposed material data with its designation, revision, units and test conditions. Distinguish typical values from guaranteed minima or ranges. Confirm which data and records apply to the quoted part.
Arnold’s NdFeB reference illustrates the trade-off between energy product and intrinsic coercivity. Its published grades and values describe Arnold materials; they are not Magnetstek supply specifications.
From material to part
State field or force, measurement location, working gap, fixture and acceptable range. Include the mating steel or other magnetic-circuit parts.
Give continuous and peak temperatures, exposure duration, cycling and any opposing magnetic field. Include assembly processes such as adhesive curing.
Send dimensions, tolerances, pole direction and critical fits. Mark whether dimensions apply after coating and identify thin sections or holes.
List material data, demagnetization curves, polarity checks and sample or first-article records needed for acceptance. Confirm availability with the quote.
Share an existing grade where one is specified. Identify which requirements are fixed and which can be discussed. Grade, geometry and quantity must be reviewed together before availability, minimum order or lead time can be confirmed.
Engineering reference
No. The higher number describes a higher energy-product class, not a universal application ranking. Compare the same finished geometry and magnetic circuit at the intended temperature, then consider the required coercivity and acceptance criteria.
No. A published rating has assumptions about the material and its working point. Geometry, air gap, the surrounding circuit and opposing fields affect demagnetization risk. Review the proposed grade’s temperature-dependent curves with the finished design.
A single surface reading does not establish all of the material properties. The measured field also depends on geometry, magnetization, probe position and test arrangement. Specify a material-document review and a separate finished-part magnetic check where both are required.
Compare the actual property ranges, coercivity, temperature-dependent curves and conditions. Confirm the proposed material designation and the substitution approval on the drawing or purchase specification. Similar names alone are insufficient.
Yes, where it changes the fit, gap, exposure or processing temperature. A magnetic grade does not specify corrosion protection or adhesive performance. Review the complete assembly alongside the material selection.
Send the current drawing, target output and known temperature range. Clearly mark unknowns and alternative geometries. Any preliminary recommendation should remain subject to the agreed design review and sample verification.
Review heat exposure and the magnetic working point.
Read the guide →Specify exposure, finished fit and surface acceptance.
Read the guide →Prepare dimensions, pole direction and inspection inputs.
Read the guide →Separate material, dimensional and assembled-output evidence.
Read the guide →For terminology, see K&J’s magnet-grade explanation. External references explain general principles; confirm the documentation for the actual material offered.
Comparing another material? Review Sm₂Co₁₇, Sm₁Co₅, bonded NdFeB or AlNiCo grades against the same application requirements.
Send your drawing for grade review